Hydraflex Duplex Hose assemblies are available as unbraided, covered with single stainless steel external wire braid or with double braid for increased working pressure. Hydraflex also offer our range of A200 & A700 Heavy-Duty Stainless-Steel Hose Series which is designed for more arduous installations and higher working pressur......Read More
Part Number:
Hydraflex Duplex Hose assemblies are available as unbraided, covered with single stainless steel external wire braid or with double braid for increased working pressure. Hydraflex also offer our range of A200 & A700 Heavy-Duty Stainless-Steel Hose Series which is designed for more arduous installations and higher working pressure applications. Typical stock range of end fittings available, in various materials such as Carbon Steel & Stainless Steel (Other materials available). - BSPT / NPT Hex Fixed Male Connections Jacket connections are typically BSPT Male, however, Hydraflex can supply these connections to suit your requirement. All end fittings listed above, for the primary hose or jacket hose connections, can be supplied in 45 Degree (135) or 90 Degree Configuration - Contact our Sales Office for more information.
- BSPT / NPT Weld Nipple Connections
- BSP Cone Seat Swivel Unions (60 Degree)
- BSP Full Male Union (Cone Seat Swivel Unions (60 Degree) with Male / Male adaptors) - (Various thread options available from stock).
- BSP Full Female Union (Cone Seat Swivel Unions (60 Degree) with Male / Female adaptors) - (Various thread options available from stock).
- BSPT / NPT Fixed Female Connections
- Flanged Connections (Fixed) - Typically PN16 / ASA 150lb (Others available from stock)
- Flanged Connections (Swivel) - Typically PN16 / ASA 150lb (Others available from stock)
- Tube End Connections (Offered as Stock OD sizes with gauge or Schedule wall thicknesses)
- Victaulic Grooved connections
DESIGN & MATERIAL CONSTRUCTION
Hose
Stainless Steel 316LBraid
Stainless Steel AISI 304/304LTemp
-269°C - +600°C
Sizes
¼” NB – 16” NB
APPLICATIONS
- Building Services
- HVAC-R Piping Lines
- Pump Connections,
- Vibration Producing Systems
- Industrial Process &Applications
- Steam connections
- Chemical Process
- Gas Connections
- Ultra-High Vacuum applications
- Exhaust systems
QUALITY & ASSOCIATED STANDARDS
All Hydraflex Metal Hoses are produced by fully penetrated TIG welding method to Hydraflex’s approved Weld procedures. Each and every Unit manufactured is 100% pressure tested to a minimum hydrostatic pressure test of 1.5 times of the design pressure. PED 2014/68/EU approval and material certificates to EN 10204 is available for all sizes.
- Ensuring that the media being conveyed is kept at a
specific temperature, typically, by using Steam or
hot water in the outer jacket.
- Absorption of Heat Expansion
- Absorption of Angular Movements
- Compensation of Parallel Pipeline Set Off
- Absorption of Oscillations
- Installation involving High and Low temperatures
- Vibration Elimination
TYPE 100 - STANDARD PITCH
| Nominal Diameter | Internal Diameter I/D (mm) | Braids | Outside Diameter O/D (mm) | Minimum Bend radius Static | Minimum Bend radius Dynamic (mm) | Maximum Safe Working Pressure (Kg/cm2) | Maximum Test Pressure (Kg/cm2) | Minimum Burst Pressure (Kg/cm2) |
|---|---|---|---|---|---|---|---|---|
| 1/4" | 6.2 | 0 | 9.6 | 25 | 85 | 12 | 18 | 48 |
| 1 | 10.8 | 120 | 180 | 480 | ||||
| 2 | 12.0 | 192 | 288 | 768 | ||||
| 3/8" | 10.3 | 0 | 14.3 | 38 | 140 | 9 | 14 | 36 |
| 1 | 15.5 | 90 | 135 | 360 | ||||
| 2 | 16.7 | 144 | 216 | 576 | ||||
| 1/2" | 12.2 | 0 | 16.7 | 45 | 140 | 9 | 14 | 36 |
| 1 | 17.9 | 80 | 120 | 320 | ||||
| 2 | 19.1 | 128 | 192 | 512 | ||||
| 5/8" | 16.2 | 0 | 21.6 | 58 | 160 | 8 | 12 | 32 |
| 1 | 23.0 | 70 | 105 | 280 | ||||
| 2 | 24.4 | 112 | 168 | 448 | ||||
| 3/4" | 20.2 | 0 | 26.8 | 70 | 170 | 4 | 6 | 16 |
| 1 | 28.3 | 64 | 96 | 256 | ||||
| 2 | 29.8 | 102 | 153 | 410 | ||||
| 1" | 25.4 | 0 | 32.2 | 85 | 190 | 3 | 5 | 12 |
| 1 | 33.7 | 50 | 75 | 200 | ||||
| 2 | 35.2 | 80 | 120 | 320 | ||||
| 1 1/4" | 34.3 | 0 | 41.1 | 105 | 260 | 2 | 3 | 8 |
| 1 | 42.7 | 40 | 60 | 160 | ||||
| 2 | 44.3 | 64 | 96 | 256 | ||||
| 1 1/2" | 40.1 | 0 | 49.5 | 130 | 300 | 1 | 2 | 4 |
| 1 | 51.2 | 35 | 53 | 140 | ||||
| 2 | 52.7 | 56 | 84 | 224 | ||||
| 2" | 50.3 | 0 | 60.3 | 160 | 320 | 1 | 2 | 4 |
| 1 | 62.5 | 30 | 45 | 120 | ||||
| 2 | 64.3 | 48 | 72 | 192 |
TYPE 200 - STANDARD PITCH
| Nominal Diameter | Internal Diameter I/D (mm) | Braids | Outside Diameter O/D (mm) | Minimum Bend radius Static | Minimum Bend radius Dynamic (mm) | Maximum Safe Working Pressure (Kg/cm2) | Maximum Test Pressure (Kg/cm2) | Minimum Burst Pressure (Kg/cm2) |
|---|---|---|---|---|---|---|---|---|
| 3/4" | 20.5 | 0 | 27.0 | 70 | 170 | 3 | 4.5 | 12 |
| 1 | 28.5 | 64 | 96 | 256 | ||||
| 2 | 30.0 | 102 | 154 | 410 | ||||
| 1" | 25.6 | 0 | 34.0 | 85 | 190 | 3 | 4.5 | 12 |
| 1 | 35.5 | 50 | 75 | 200 | ||||
| 2 | 37.0 | 80 | 120 | 320 | ||||
| 1 1/4" | 32.6 | 0 | 41.0 | 105 | 260 | 2 | 3 | 8 |
| 1 | 42.5 | 40 | 60 | 160 | ||||
| 2 | 44.0 | 64 | 96 | 256 | ||||
| 1 1/2" | 40.6 | 0 | 51.2 | 130 | 300 | 2 | 3 | 8 |
| 1 | 52.5 | 35 | 52.5 | 140 | ||||
| 2 | 54.0 | 56 | 84 | 224 | ||||
| 2" | 50.7 | 0 | 65.0 | 160 | 320 | 1 | 2.5 | 4 |
| 1 | 67.0 | 30 | 45 | 120 | ||||
| 2 | 69.0 | 48 | 72 | 192 | ||||
| 2 1/2" | 65.6 | 0 | 81.0 | 180 | 410 | 1 | 1.5 | 4 |
| 1 | 83.0 | 24 | 36 | 96 | ||||
| 2 | 85.0 | 38 | 58 | 154 | ||||
| 3" | 80.3 | 0 | 95.0 | 200 | 450 | 0.6 | 0.9 | 2.4 |
| 1 | 97.0 | 18 | 27 | 72 | ||||
| 2 | 99.0 | 29 | 45 | 115 | ||||
| 4" | 100.8 | 0 | 117.0 | 290 | 560 | 0.5 | 0.75 | 2 |
| 1 | 119.0 | 16 | 24 | 64 | ||||
| 2 | 121.5 | 26 | 38 | 102 | ||||
| 5" | 125.4 | 0 | 150.0 | 325 | 710 | 0.5 | 0.8 | 2 |
| 1 | 152.5 | 14 | 21 | 56 | ||||
| 2 | 155.0 | 22 | 34 | 90 | ||||
| 6" | 150.8 | 0 | 175.0 | 380 | 815 | 0.3 | 0.45 | 1.2 |
| 1 | 177.5 | 10 | 15 | 40 | ||||
| 2 | 180.0 | 16 | 24 | 64 | ||||
| 8" | 197.0 | 0 | 225.0 | 500 | 1015 | 0.3 | 0.45 | 1.2 |
| 1 | 228.0 | 8 | 12 | 32 | ||||
| 2 | 231.0 | 13 | 19 | 51 | ||||
| 10" | 250.4 | 0 | 278.0 | 620 | 1270 | 0.2 | 0.3 | 0.8 |
| 1 | 281.0 | 7.5 | 11 | 30 | ||||
| 2 | 285.0 | 12 | 18 | 48 | ||||
| 12" | 300.2 | 0 | 336.0 | 725 | 1525 | 0.2 | 0.3 | 0.8 |
| 1 | 339.5 | 6 | 9 | 24 | ||||
| 2 | 343.0 | 9.5 | 14 | 38 |
TYPE 700 – HEAVY DUTY HOSE
| Nominal Diameter | Internal Diameter I/D (mm) | Braids | Outside Diameter O/D (mm) | Minimum Bend radius Static | Minimum Bend radius Dynamic (mm) | Maximum Safe Working Pressure (Kg/cm2) | Maximum Test Pressure (Kg/cm2) | Minimum Burst Pressure (Kg/cm2) |
|---|---|---|---|---|---|---|---|---|
| 3/4" | 20.2 | 0 | 28.0 | 58 | 203 | 4 | 6 | 16 |
| 1 | 29.5 | 65 | 97.5 | 260 | ||||
| 1" | 25.4 | 0 | 38.0 | 70 | 230 | 3 | 4.5 | 12 |
| 1 | 39.5 | 50 | 75 | 200 | ||||
| 1 1/4" | 32.5 | 0 | 46.5 | 90 | 267 | 2 | 3 | 8 |
| 1 | 48.5 | 45 | 67.5 | 180 | ||||
| 1 1/2" | 40.5 | 0 | 55.5 | 102 | 305 | 2 | 3 | 8 |
| 1 | 58.0 | 38 | 57 | 152 | ||||
| 2" | 50.5 | 0 | 66.0 | 127 | 381 | 1 | 1.5 | 4 |
| 1 | 68.0 | 38 | 57 | 152 | ||||
| 2 1/2" | 65.5 | 0 | 82.0 | 203 | 508 | 1 | 1.5 | 4 |
| 1 | 84.0 | 28 | 42 | 112 | ||||
| 3" | 80.1 | 0 | 96.0 | 240 | 560 | 0.6 | 0.9 | 2.4 |
| 1 | 98.5 | 23 | 34.5 | 92 | ||||
| 4" | 100.8 | 0 | 123.0 | 290 | 686 | 0.5 | 0.8 | 2 |
| 1 | 126.0 | 20 | 30 | 80 | ||||
| 5" | 125.2 | 0 | 150.0 | 353 | 788 | 0.5 | 0.8 | 2 |
| 1 | 153.0 | 14 | 21 | 56 | ||||
| 6" | 150.7 | 0 | 175.0 | 400 | 915 | 0.3 | 0.5 | 1.2 |
| 1 | 178.0 | 14 | 21 | 56 |
TEMPERATURE / PRESSURE CORRECTION
| 0°C | 50°C | 100°C | 150°C | 200°C | 250°C | 300°C | 350°C | 400°C | 450°C | 500°C | 550°C | ||
| % Pressure Bar | 100% | 90% | 73% | 67% | 61% | 58% | 53% | 51% | 50% | 49% | 47% | 47% |
|---|
REDUCTION COEFFICIENT OF PRESSURE AS A FUNCTION OF TEMPERATURE

END FITTINGS – HALF SECTION

PRESSURE DROP
The Pressure loss in corrugated hose is 100% higher than in new welded steel pipes. This means that in the case of corrugated hose an increase in diameter of approximately 15% is required to reduce the pressure loss to the
value of pressure loss in steel pipes. To utilise the chart...
- Identify the flow rate required on the base line (Horizontal Axis).
- Where the vertical line, that references to the nominal bore of the hose, intersects a horizontal line - Establish the pressure drop on the Vertical Axis. (Any data provided is for reference only. Please contact our Sales Team for additional information if required)
FLEXING INSTALLATIONS CHART

INSTALLATION GUIDE- DO’S & DON’T’S

LENGTH MEASURE POINTS