Hydraflex's Oxystop range offers a low oxygen permeable hose that is an ideal choice for heating and ventilation applications such as chilled ceilings. This range is suitable for the conveyance of water in the temperature range of -20°C to +90°C and in systems that include glycol inhibitors or additives. Oxystop assemblies are fully be......Read More
Part NumberIDOverall LengthFitting 1Fitting 2Purchase Options
OS13MCMB3013mm300mm1/2" Male15mm CompressionPOA
OS13TCTC3013mm300mm15mm Tectite15mm TectitePOA
OS13MBMB3013mm300mm15mm Compression15mm CompressionPOA
OS13FPFP3013mm300mm1/2" Female1/2" FemalePOA
OS13MCNC3013mm300mm1/2" Male15mm PushfitPOA
OS13MCTC3013mm300mm1/2" Male15mm TectitePOA
OS13NCNC3013mm300mm15mm Pushfit15mm PushfitPOA
OS10NCNC3010mm300mm10mm Pushfit10mm PushfitPOA

Hydraflex's Oxystop range offers a low oxygen permeable hose that is an ideal choice for heating and ventilation applications such as chilled ceilings. This range is suitable for the conveyance of water in the temperature range of -20°C to +90°C and in systems that include glycol inhibitors or additives. Oxystop assemblies are fully bespoke to specific projects or client requirements and identifiable by the blue fleck in the overbraid. With customisable lengths and fittings including threaded fittings or push fits to ensure hassle free installation.

Hose
Butyl Liner
Braid
304 Stainless Steel
Metal Fittings
CW617N/CW614N
  • Low Oxygen Permeability
  • High Flexibility
  • Longer Heat Stability
Compared to EPDM and Thermoplatic hose assemblies the Hydraflex Oxystop assemblies provide excellent resistance to oxygen. Under test conditions the oxygen permeation for the HF Oxystop range was 0.035 g/m2, with a DN4726 limit requiring a maximum permeability of 10 g/m2 per day. In similar tests EPDM was 150 g/m2 whilst Thermoplastic were more than 150 g/m2.
  • Low Oxygen Permeability
  • High Flexibility
  • Longer Heat Stability
  Our class O insulation is made from Elastomeric Foam Based on Synthetic Rubber with antimicrobial and fibre-free structure, the material meets high hygienic requirements and is especially suitable for insulation in healthcare facilities like hospitals. Even at low insulation thickness, this proven material protects long-term energy losses, acts as an effective water vapour barrier and so minimizes the risk of corrosion under insulation.
Hose Part Number ID OD Working Pressure @ 20°C Burst Pressure Minimum Assembly Cut Length Bend Radius
MM MM Bar Bar MM MM
OX06 6 10 15 110 80 26
OX08 8 12 15 110 80 17
OX10 10 15 15 100 150 35
OX13 13 18 15 80 150 45
OX16 16 22 12 70 150 70
OX19 19 27 10 60 180 80
OX25 25 33 10 50 180 100
OX32 32 43 10 40 230 160
Diagram 2 displaying the overall length and cut length of a hose assembly
The arrow on drawing D2 denotes the 'R' measurement showing the 'Minimum Bore Through Fittings (mm)' which is reduced through the fitting tail, with a tolerance of +/- 0.2mm. The below measurements represent the minimum bore of each DN size; however, fittings will vary in bore size. For further information regarding this please contact out technical department.
DN Size Hose Bore (Inches) Hose Bore (mm) R = Minimum Bore Through Fittings (mm)
DN06 1/4" 6 4.2
DN08 5/16" 8 5.7
DN10 3/8" 10 6.7
DN13 1/2" 13 8.7
DN19 3/4" 19 14.8
DN25 1" 25 19.8
DN32 1 1/4" 32 25.5
DN40 1 1/2" 40 31.8
DN50 2" 50 40.4