DESIGN & MATERIAL CONSTRUCTION

Hose

Stainless Steel 321L

DESCRIPTION

HydraFlex - Unbraided Stainless Steel 321 Annular Corrugated Hose c/w an external yellow cover. They are manufactured to reduce possible vibration and offer a high degree of flexibility allowing for misalignment of pipework. This range of hose assemblies conforms to Section 9.5a of BS 6896 : 1991. The hose is manufactured in accordance with ISO 10380 – 2012. Installations with working pressures less than 0.5 Bar are exempt from the PED. Typical end connections are on one end terminated with a BSP swivel female c/w a BSPP/BSPT Male/Male adaptor other end with a BSPT fixed Hex Male connection. (End connections in Carbon Steel) - however other variation are available on request.

APPLICATIONS

- Gas connections

QUALITY & ASSOCIATED STANDARDS

All Hydraflex Metal Hoses are produced by fully penetrated TIG welding method acc. To Hydraflex’s approved WPSs. Each and every Metallic Hose 100% tested and is exposed to hydrostatic pressure test @1.5 times of the design pressure. PED 2014/68/EU approval and material certificates acc. to EN 10204 is available for all sizes
- Unbraided Gas Connector Assemblies are used for the final connection to Gas Fired Radiant and Warm Air Heaters.

HOSE DATA

TYPE 100 - STANDARD PITCH

TYPE 200 - STANDARD PITCH

TYPE 700 – HEAVY DUTY HOSE

TEMPERATURE / PRESSURE CORRECTION

REDUCTION COEFFICIENT OF PRESSURE AS A FUNCTION OF TEMPERATURE

END FITTINGS – HALF SECTION

PRESSURE DROP

The Pressure loss in corrugated hose is 100% higher than in new welded steel pipes. This means that in the case of corrugated hose an increase in diameter of approximately 15% is required to reduce the pressure loss to the
value of pressure loss in steel pipes. To utilise the chart...

  1. Identify the flow rate required on the base line (Horizontal Axis).
  2. Where the vertical line, that references to the nominal bore of the hose, intersects a horizontal line - Establish the pressure drop on the Vertical Axis. (Any data provided is for reference only. Please contact our Sales Team for additional information if required)

FLEXING INSTALLATIONS CHART

INSTALLATION GUIDE- DO’S & DON’T’S

LENGTH MEASURE POINTS

FURTHER INFORMATION 

For any more information that you may require then please contact one of our team. 

Northampton: 01604621964  Bolton: 01204529536  Rugby: 01604621964

Email: [email protected]

Technical Info

UNIT C, Spring Lane, Northampton, NN1 2JW

+44 (0)1604 621 964
[email protected]

DOWNLOAD TECHNICAL DATA SHEET

Start typing to see products you are looking for.